Yassilash sinovini qabul qilish mezonlari quyidagilar bo'lishi kerak:
EW quvurlari D<12.750 in:
T 500 dyuymli X60. Plitalar orasidagi masofa asl tashqi diametrning 66% dan kam bo'lishidan oldin payvand chokining ochilishi bo'lmasligi kerak. Barcha sinflar va devor uchun 50%.
D/t > 10 bo'lgan quvur uchun plitalar orasidagi masofa asl tashqi diametrning 30% dan kam bo'lishidan oldin payvand chokining ochilishi bo'lmasligi kerak.
Boshqa o'lchamlar uchun to'liq API 5L spetsifikatsiyasiga qarang.
| Chelik darajasi | Massa ulushi, % issiqlik va mahsulot tahlillari asosida a,g | ||||||
|---|---|---|---|---|---|---|---|
| C | Mn | P | S | V | Nb | Ti | |
| maksimal b | maksimal b | maks | maks | maks | maks | maks | |
| Choksiz quvur | |||||||
| A | 0.22 | 0.9 | 0.3 | 0.3 | – | – | – |
| B | 0.28 | 1.2 | 0.3 | 0.3 | c,d | c,d | d |
| X42 | 0.28 | 1.3 | 0.3 | 0.3 | d | d | d |
| X46 | 0.28 | 1.4 | 0.3 | 0.3 | d | d | d |
| X52 | 0.28 | 1.4 | 0.3 | 0.3 | d | d | d |
| X56 | 0.28 | 1.4 | 0.3 | 0.3 | d | d | d |
| X60 | 0.28 e | 1.40 e | 0.3 | 0.3 | f | f | f |
| X65 | 0.28 e | 1.40 e | 0.3 | 0.3 | f | f | f |
| X70 | 0.28 e | 1.40 e | 0.3 | 0.3 | f | f | f |
PSL2 uchun CVN ta'sir testi
Ko'pgina PSL2 quvurlari o'lchamlari va navlari CVN ni talab qiladi. Choksiz quvur tanada sinovdan o'tkazilishi kerak. Payvandlangan quvur korpusda, trubaning payvandida va issiqlik ta'sirlangan zonada sinovdan o'tkazilishi kerak. O'lchamlar va navlar jadvali va kerakli so'rilgan energiya qiymatlari uchun to'liq API 5L spetsifikatsiyasiga qarang.